| Design Criteria |
| Max/Min Operating Water Depth: |
154/30 ft |
| Max Rated Drilling Depth: |
20,000 ft |
| Storage Capacities |
| Fuel Oil: |
28,040 ft3 (794 m3) |
| Lube oil: |
141 ft3 (4.0 m3) |
| Drilling Water: |
30,618 ft3 (867 m3) |
| Potable Water: |
14,126 ft3 (400m3) |
| Bulk Mud: |
5,933 ft3 (168 m3) |
| Bulk Cement: |
5,933 ft3 (168 m3) |
| Heavy Mud Accepted: |
389 ft3 (11 m3) |
| Total of Active Mud and Reserve Mud: |
(330 m3) |
| Sack Storage: |
4000(sacks) |
| Main Dimensions |
| Length Overall£º |
311¡¯ (94.7 meters) |
| Length of Hull: |
213' (64.92meters) |
| Breadth of Hull: |
212¡¯ (64.92 meters) |
| Depth of Hull: |
27¡¯ (8.27 meters) |
| Overall Length of Leg: |
290 ft including Spud Cans |
| Number of Legs: |
3 |
| Type of Legs: |
Independent/Triangular |
| Heli-Deck Diameter: |
75' x 75¡¯ |
| Max. Cantilever Combined Load: |
2,000 kips at 0ft |
| 660 kips at 60ft |
| Living quarters: |
106 persons per UK HSE |
| Maximum Gross Variable Load |
| Transit VL: |
3,924kips (1780t) |
| Drilling VL: |
5,500kips (2500t) |
| Survival VL: |
3,924kips (1780t) |
| Jacking VL: |
2,646kips (1200t) |
| Power Equipment |
| Main Diesel: |
Caterpillar 3516 DITA |
| Diesel Engines: |
1230.5KW x 4, 1200 rpm |
| Main Generators: |
1950KVAx5, 60Hz, 0.6pf |
| DC MOTOR Drilling System: |
5 EA, 1200KW, TPC |
| Drilling Equipment |
| Draw works: |
National 1320-UE |
| Derrick: |
PYRAMID base30¡¯x30¡¯ up 8¡¯x8¡¯ high 147¡¯ |
| Traveling Block: |
National 650G500 6x60 |
| Crown Block: |
National 760-FA 7x60 |
| Top Driver: |
VARCO IDS-1 |
| Rotary Table: |
National C-375 |
| BOP Equipment |
| BOP Stack: |
One Set Shaffer 13-5/8" 15K |
| One Set Hydril 21-1/4¡± 2K BOP Stack |
| BOP Control System: |
KOOMEY Offshore System Inc |
| Accommodation |
| Company Representative¡¯s Office: |
2 |
| Contractor¡¯s Representative¡¯s Office: |
1 |
| Control Room: |
1 |
| Radio Room: |
1 |
| Helicopter Assembly Room: |
1 |
| Hospital / No of Beds |
1/1 |
| Accommodations: |
|
Number of double rooms:
|
7 |
Number of 4 mens rooms:
|
6 |
| Number of 6 mens rooms: |
10 |
| Number of 8 mens rooms: |
1 |
| Toilets: |
14 |
| Showers: |
14 |
| Galley: |
1 |
| Recreation Room: |
1 |
| Gym: |
1 |
| Changing Room: |
1 |
| Deck Crane |
| Crane: |
Two Amclyde Unit 10000HD &One National Oilwell 60DNS110-1.75 |
| Location: |
Port/Stb fwd/Stb Aft. |
| Boom Length: |
110ft |
| Block capacities and hoisting speeds: |
|
| Load/Radius/Speed(min.radius): |
46/25 /1.1t/ft (ft/sec) |
| Load/Radius/Speed(max.radius): |
12/110/5.2t/ft (ft/sec) |
| Jacking Systems and Rack chock system |
| Make/type: |
NATIONAL/4-PINION |
| No. of jacks: |
48 units |
| Maximum normal jacking capacity: |
800 kips/units |
| Maximum preload jacking capacity: |
800 kips/units |
| Jacking speed: |
1.0 ft/min |
| Rack chocks available: |
Yes |